DT-UNI Tester
The “DT-UNI” device is designed for testing and control of high-pressure fuel pumps with electronic control of the distribution type, as well as in-line injection pumps.
Distribution type VE - in particular Bosch HDK and EDC, as well as Japanese manufacturers of injection pumps ZEXEL in particular COVEC-F. Series injection pump type: PE.
The device “DT-UNI” enable:
• operate fuel injection pump with electronic controls;
• set any possible position of the valve-spool (dispenser);
• operate pumps, with “inductive” or “potentiometric” position sensor;
• control the voltage (checkback) of the feedback from the sensor position of the dispenser on the indicator;
• monitor the preset voltage on the dispenser;
• monitor the current value through the coil of the dispenser;
• monitor the fuel temperature in the injection pump;
• operate the position of the fuel injection timing valve;
• display the voltage of the so-called “advance valve stroke” (TPS), only for ZEXEL-COVEC.
• start the engine directly using the “DT-UNI” device;
• control the operation of the fuel pump without removing it from the vehicle;
Specification
| Electric power supply voltage | 220V ± 15% |
|---|---|
| External electric power supply voltage | + 10 ... + 16V |
| The maximum permissible long-time current of the control circuit of the electromagnet of the dispenser | 10A |
| The maximum permissible short-time current of the control circuit of the electromagnet of the dispenser | 12A |
| Operating threshold of the operation current by a solenoid | ~ 13А |
| Operating threshold of the operation current of the 2nd control channel (advanced) | 4A (VE, ZEXEL) and 13A (PE) |
| Measurement error of the feedback voltage from the slide valve | no more than 2.5% |
| TPS voltage measurement error | no more than 5% |
| Temperature measurement error | 5% |
| Current measurement error (at a current of more than 0.2 A) | no more than 6% |
| The mass of the device is not more than 5 Kg | |
| Dimensions (length x width x height) | 230x220x150 |
| Power consumption | no more than 250 W |
Packaging
| Manual | 1 pcs. |
|---|---|
| Controller DT-UNI | 1 pcs. |
| Extension cable VE / ZEX | 1 pcs. |
| Extension cable PE | 1 pcs. |
| Cable TIMING ADVANCE VE / ZEX | 1 pcs. |
| Cable-adapter "SPIDER-VE" | 1 pcs. |
| Cable adapter VE-VOLKSWAGEN (0.986.612.439) | 1 pcs. |
| Power cable 220V | 1 psc. |
Documentation
- DT-UNI manual PDF, 2.2 MB
- DT-UNI manual EN PDF, 1.5 MB
Downloads
- DT_Uni_1.5.2.exe Software EXE, 3.6 MB